Flue system for combustion stove

Condor Flue System

Select location for heater flue system ensuring that there are no obstructions such as joists, rafters, etc.

The hole centres in ceiling and roof can be found by means of a ‘plumb bob’ hung down the into the spigot on stove.

Cut hole in ceiling to diameter of manifold casing (approx 255mm dia.)

Locate and fasten welded angle cross bracket to joists above hole and fasten into position.

Cut hole in roof and fit roof flashing/casing in perpendicular line to ceiling hole.

Slide Ceiling Manifold casing through hole into welded angle cross bracket, and fasten at four points with stainless steel rivets.

Extend telescopic casing up into roof flashing /casing and fasten to roof casing per diagram ( fasten casing extension where necessary before extending telescopic section )

Locate Primary Casing Vent assembly to roof Flashing Casing and fasten using stainless steel rivets.

The stainless steel fluing is assembled and installed so that the uppermost section is inside the lower.

The Manifold Vent is installed prior to the last section of stainless fluing being fitted to installation. As the fluing is introduced to the casing from below Condor does not promote the fastening of stainless steel fluing using mechanical fasteners however if this is desired then stainless steel rivets should be used.

The discharge terminal is installed once the stainless steel fluing assembly has been installed so as only 25mm protrudes from the height of the secondary casing.

Share:

Share on facebook
Facebook
Share on twitter
Twitter
Share on pinterest
Pinterest
Share on linkedin
LinkedIn

Product Category

Latest Notes

Get The Latest Updates

Subscribe To Our Weekly Newsletter

No spam, notifications only about new products, updates.
On Key

Related Notes

Ductless Range Hood

Ductless / Re circulating Range Hoods This ventilation concept would have to be one of the classic products devised to entice the unaware in a

Read More »

Roof Services Industry

Roof Services Industry With the avaricious consumption of poor quality roof ventilation and skylight products as exists at present, and given the average life expectancy

Read More »

Sub Floor Ventilation

Sub Floor Ventilation by Isa Stralian The purpose of venting the area beneath a floor, particularly a timber floor, is to prevent the incidence of wood

Read More »